聯係方式 |
| 電話(市場部):0517-86851868 |
|
| (拓展部): |
| 傳真: |
節假日商務聯係電話:
何經理:
紀經理: |
| 郵編:211600 |
| 網址:http://007gupiao.cn/ |
| http://www.sukeyb.com/ |
| E-mail: |
| |
地址:江蘇省金湖縣工業園區環城西
路269號 |
|
|
SK-LX型楔形流量計
|
SK-LX型楔形流量計是一種差壓式流量儀表,它是利用在密閉管道中能量相互轉換的伯努利定律,即:在zai穩wen定ding流liu體ti場chang合he中zhong,管guan道dao中zhong的de流liu速su與yu差cha壓ya的de平ping方fang根gen成cheng正zheng比bi。楔xie形xing流liu量liang計ji是shi八ba十shi年nian代dai開kai始shi開kai始shi逐zhu步bu走zou向xiang實shi用yong的de一yi種zhong新xin型xing流liu量liang計ji,其qi檢jian測ce件jian是shi一yi個geV字形楔塊(又稱楔形節流件),tadeyuanhuadingjiaochaoxia,zheyangyouliyuhanxuanfukelideyetihuozhanchouyetishunlitongguo,buhuizaijieliujianshangyoucechanshengzhiliu。liutitongguoxiexingliuliangjishi,youyuxiekuaidejieliuzuoyong,zaiqishang、下遊側產生了一個與流量值成平方關係的差壓,將此差壓從楔塊兩側取壓口引出送至差壓變送器轉變為電信號輸出,再經專用智能流量積算儀運算後,即可顯示流量值。
一、楔形流量計流量方程:

式中 qv----體積流量計,m³/s C------流出係數;
ε-----可膨脹係數; m------節流麵積比; D------管道內徑,m; △p------差壓,pa; ρ------被測介質密度,kg/m³
SK-LX型楔形流量計具有流量係數、非線性誤差、溫度變化、密度變化等參數的修正功能;測量精度可達0.5%;可具有現場顯示和標準電流信號(4~20mA DC)輸出,可方便地用於自動控製係統或與計算機聯網,進行流量或其他參數的自動調節和控製。
SK-LX型楔形流量計可以在高粘度、低雷諾數(雷諾數>500即可使用)的流體情況下進行精度佳的流量測量;在流速較低、流量小、管徑大的流量測量場合有不可替代的作用。主要用於高粘度(重油、渣油、柴油、機油等)、工業煤氣(焦爐煤氣、高爐煤氣、發生爐煤氣、城市煤氣)、氫氣、氮氣、空氣、水蒸汽、汙水液體等介質的流量測量。
楔形流量計結構簡單、無可動部件,不易被流體磨損,工作性能穩定、可靠,使用壽命長;它(ta)的(de)測(ce)量(liang)元(yuan)件(jian)及(ji)取(qu)壓(ya)裝(zhuang)置(zhi)結(jie)構(gou)特(te)殊(shu),流(liu)體(ti)通(tong)過(guo)時(shi)不(bu)形(xing)成(cheng)滯(zhi)留(liu)或(huo)堵(du)塞(sai),壓(ya)力(li)損(sun)失(shi)較(jiao)小(xiao),是(shi)在(zai)雷(lei)諾(nuo)數(shu)較(jiao)低(di)的(de)情(qing)況(kuang)下(xia)進(jin)行(xing)精(jing)度(du)佳(jia)流(liu)量(liang)測(ce)量(liang)的(de)理(li)想(xiang)選(xuan)擇(ze)。
二、主要特點:
1、特別適合於高粘度、低雷諾數、帶懸浮顆粒或氣泡的介質測量;
2、測量精度不受流體介質介電常數等特性的影響和限製;
3、楔形件結構設計特殊,有導流作用,防堵塞;
4、具有流體粘度變化、溫度變化、密度變化等補償功能;
5、抗振動、抗衝擊、抗髒汙、抗腐蝕;
6、具有雙向流量測量功能;
7、測量精度高;
8、結構簡單、牢固、高可靠性,安裝方便,運行維護費用低;
9、無運動部件、無磨損,長期使用時不需要重新標定。
三、技術參數:
1、測量精度: ±1.0%~±1.5%
2、最低流速:0.01m/s。
3、使用壽命:可長達十年以上。
4、量程比≥10:1
5、雷諾數係數使用範圍:下限300,上限達1×106以上。
6、測量液體粘度上限:500MPa•S。
7、工作壓力範圍:-0.1~6.4MPa。
8、工作溫度範圍:-50~400℃。 四、流量範圍
1、楔形流量計測量液體時的流量範圍:
| 型號 |
公稱通徑DN(mm) |
楔形比(H/D) |
流量範圍(m³/h) |
LX015 |
15 |
0.2,0.3,0.4,0.5 |
0.11~2.7 |
LX020 |
20 |
0.2,0.3,0.4,0.5 |
0.2~4.8 |
LX025 |
25 |
0.2,0.3,0.4,0.5 |
0.3~7.4 |
LX032 |
32 |
0.2,0.3,0.4,0.5 |
0.5~12.2 |
LX040 |
40 |
0.2,0.3,0.4,0.5 |
0.8~19 |
LX050 |
50 |
0.2,0.3,0.4,0.5 |
1.3~29.7 |
LX065 |
65 |
0.2,0.3,0.4,0.5 |
2.2~50.1 |
LX080 |
80 |
0.2,0.3,0.4,0.5 |
3.3~76 |
LX100 |
100 |
0.3,0.4,0.5 |
8.2~118.7 |
LX125 |
125 |
0.3,0.4,0.5 |
12.8~185.5 |
LX150 |
150 |
0.3,0.4,0.5 |
18.4~267.1 |
LX200 |
200 |
0.3,0.4,0.5 |
32.7~474.8 |
LX250 |
250 |
0.3,0.4,0.5 |
51.2~741.8 |
LX300 |
300 |
0.3,0.4,0.5 |
73.8~1068.2 |
2、楔形流量計測量氣體時的流量範圍:
| 型號 |
公稱通徑DN(mm) |
楔形比(H/D) |
流量範圍(m³/h) |
LX015 |
15 |
0.2,0.3,0.4,0.5 |
1.2~19.1 |
LX020 |
20 |
0.2,0.3,0.4,0.5 |
2.3~33.9 |
LX025 |
25 |
0.2,0.3,0.4,0.5 |
3.5~53 |
LX032 |
32 |
0.2,0.3,0.4,0.5 |
5.8~86.8 |
LX040 |
40 |
0.2,0.3,0.4,0.5 |
9.0~135.7 |
LX050 |
50 |
0.2,0.3,0.4,0.5 |
14.1~212 |
LX065 |
65 |
0.2,0.3,0.4,0.5 |
23.9~358.2 |
LX080 |
80 |
0.2,0.3,0.4,0.5 |
36.2~542.6 |
LX100 |
100 |
0.3,0.4,0.5 |
56.5~847.8 |
LX125 |
125 |
0.3,0.4,0.5 |
88.3~1324.5 |
LX150 |
150 |
0.3,0.4,0.5 |
127.2~1907.6 |
LX200 |
200 |
0.3,0.4,0.5 |
226.1~3391.2 |
LX250 |
250 |
0.3,0.4,0.5 |
353.3~5298.8 |
LX300 |
300 |
0.3,0.4,0.5 |
508.7~7630.2 |
楔形流量計選型:
| 型譜 |
代號 |
外殼材質 |
公稱壓力 |
工作溫度 |
連接與取壓方式 |
說明 |
SKLX |
|
|
|
|
|
楔形流量計 |
|
015 |
|
|
|
|
DN15 |
020 |
|
|
|
|
DN20 |
025 |
|
|
|
|
DN25 |
… |
|
|
|
|
|
300 |
|
|
|
|
DN300 |
|
I |
|
|
|
碳鋼 |
II |
|
|
|
不鏽鋼 |
III |
|
|
|
特殊訂做 |
|
0.25 |
|
|
0.25MPa |
0.60 |
|
|
0.6MPa |
… |
|
|
|
5 |
|
|
5MPa |
|
A |
|
-20~100℃ |
B |
|
100~250℃ |
C |
|
250~400℃ |
|
A |
螺紋取壓對夾式 |
B |
螺紋取壓螺紋式 |
C |
螺紋取壓焊接式 |
D |
螺紋取壓法蘭式 |
E |
法蘭取壓法蘭式 |
F |
一體化安裝方式(溫壓補償) |
G |
一體化安裝通用式 |
五、安裝注意事項:
1、一yi般ban楔xie形xing流liu量liang傳chuan感gan器qi有you前qian後hou測ce量liang管guan,可ke在zai水shui平ping或huo垂chui直zhi安an裝zhuang及ji使shi用yong。當dang傳chuan感gan器qi在zai垂chui直zhi管guan道dao上shang安an裝zhuang時shi,流liu體ti應ying自zi上shang而er下xia流liu動dong。測ce量liang液ye體ti時shi應ying注zhu意yi使shi差cha壓ya變bian送song器qi能neng排pai除chu氣qi泡pao,以yi免mian引yin起qi儀yi表biao零ling點dian漂piao移yi;
2、傳感器上下遊側應配置直管段,管道內壁應光滑、清潔、無附著物,直管段長度要求請詳細閱讀說明書。
3、水平安裝時,楔式差壓元件應與管道中心線成90°。對於垂直安裝,由於取壓點之間輕微的靜壓影響必須注意差壓變送器調零。
六、結構形式:
楔形流量計按其組裝方式分為一體型和分離型,按其連接方式分為法蘭連接、焊接連接、螺紋連接及對夾式連接,按其取壓方式分為普通取壓、法蘭密封取壓等結構。
|
|
|